Electrical Specifications
* Input range:90-264VAC
* Frequency: 47-63Hz
* Maximum Output Power: 150 Watts
* Short circuit protection
* Overload protection * Over voltage protection
Safety/EMC Standards
* UL 62368-1 / UL 60950-1
* CSA C22.2-No. 62368 / 60950-1
* TUV EN62368-1/ EN60950-1
* CB IEC 62368-1/ CB IEC 60350-1 * FCC Class B
* CISPR22 Class B
*EN 55032 Class B
Model | Output Rating | Po | O/P Regulation | Ripple & Regulation Noise(Vp-p) | Efficiency Level | |
---|---|---|---|---|---|---|
1079-1210 | 12V | 11.67A | 140W | ±5% | 120mV | VI |
1080-1588 | 16V | 9.38A | 150W | ±5% | 160mV | VI |
1081-1196 | 19V | 7.90A | 150W | ±5% | 190mV | VI |
1082-2877 | 24V | 6.25A | 150W | ±3% | 200mV | VI |
1083-2877 | 36V | 4.17A | 150W | ±3% | 200mV | VI |
1084-4893 | 48V | 3.13A | 150W | ±3% | 200mV | VI |
Note: 1. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
2.The switching frequency of this series Is set within 45 to 55KHz at full load
Medical-Grade versions are also available.